Digital Oscilloscope "ViewGo II" DS-5400A Series Specifications

  DS-5424A DS-5422A DS-5414A DS-5412A
Frequency bandwidth (-3dB) 200MHz 100MHz
Rise time
(Representative values)
1.75ns 3.5ns
Number of input channels 4 2 4 2
Maximum sampling speed 2GS/s (when channels are coupled), 1GS/s (when all channels are used)
Equivalent sampling speed 100GS/s
Peak detection resolution 1ns
Averaging function 2 to 256 times (power of 2 steps)
Memory length 500k point/ch (all channels)
Vertical resolution 8-bit
Input voltage range 2mV/div ~ 10V/div
Offset voltage 2mV/div ~ 50mV/div : ±1V, 50.2mV/div ~ 500mV/div : ±10V, 502mV/div ~ 10V/div : ±100V
Deskew 0~500 ns
DC gain accuracy ±(1.5% +0.5% full-scale)
Maximum input voltage ±400 Vpk
Bandwidth limit filter Analog type:20MHz,2MHz, 200kHz
Input coupling GND, DC 1MΩ, AC1MΩ
Input impedance 1 MΩ±1.0 % || 20 pF±2 pF(DC1MΩ)
Probe sense Auto search:1:1, 10:1, 100:1, 1000:1
Manual setting:1:1, 5:1, 10:1, 20:1, 50:1, 100:1, 200:1, 500:1, 1000:1, 2000:1
Time axis range 2ns/div ~ 50s/div 5ns/div ~ 50s/div
Standard probe SS-0130R (with standard number of channels)
Roll mode 50ms/div ~ 50s/div (100kS/s max)
Clock accuracy ±10 ppm
Trigger function
Trigger function Edge, number of pulses, pulse width, period, missing, TV
Trigger mode AUTO, NORMAL, SINGLE, STOP
TV trigger (standard)/Line setting range selection/
Field selection
NTSC, PAL, Custom/up to 3000/1, 2, 4, 8
Pulse number trigger setting range 1 to 9999 events
Pulse width trigger time setting range 15ns~50s
Cycle trigger time setting range 40ns~50s
Missing (dropout)
Trigger time setting range
50ns~50s
Trigger source All channels, EXT (±0.5V), EXT10 (±5.0V), line
Trigger slope/Coupling Positive, negative/AC, DC, high frequency removal, low frequency removal, noise removal
Display/Resolution
Display/Resolution 7.5-inch color TFT LCD (touch screen)/ VGA:640 x 480 pixels
Display format YT, XY, XY Trigger
Vector connection Sample point interpolation display, dot display
Analog persistence Solid tone display, spectrum display
Persistence display time 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s,infinity
Save internal waveform
(REF memory)
5 waveforms
AUTO SETUP function Can be set to Enabled or Disabled
Front panel settings save Five settings can be saved in the internal memory or USB memory device
Parameter measurement, cursor, zoom, math, replay
Parameter measurement Maximum value, minimum value, peak value, RMS value, cycle RMS value, average value, cycle average value, top, base, top-base, rising overshoot, falling overshoot, rising time 20-80%, falling time 80-20%, rising time 10-90%, falling time 90-10%, frequency, cycle, number of pulses (positive), number of pulses (negative),
pulse width (positive), pulse width (negative), duty ratio, integral, skew (positive/negative), skew @ level
Number of simultaneous measurements/statistical value display Maximum 4 parameters/maximum value, minimum value, number of measurements
Cursor Time, Amplitude, Time & Amplitude, Value at Cursor
Zoom Press the Zoom button on the front panel to display the magnified waveform in a different grid
Math function Addition, subtraction, multiplication, FFT
(up to 8k points, rectangular, Hanning, flat top window function)
Rescale/unit conversion a * x + b (x: input voltage, a, b: user-defined)/volt, ampere, watt, °C, no display
Replay Automatic waveform recording, up to 1024 waveforms can be saved and replayed
Frequency counter 6-digit
Interface USB 2.0HS support (device, host), GPIB (factory option DS-576)
AUX interface Connector for external option
Waveform data save Save to USB memory device with binary, ASCII, Mathcad, arithmetic (ASCII), and arithmetic (Mathcad)
Hard copy output Save the image to a USB memory device in TIFF, BMP, or PNG (Transparent) format
or output to a PictBridge® -compatible printer
Calibration signal output Square wave 1kHz, 3Vp-p
Power supply/power consumption AC100~240Vrms(50/60Hz), AC100V~120V(400Hz) / 95VA(60W)max
Dimensions/Body weight Approx. 330Wx190Hx124D mm/Approx. 3.7kg
Environmental conditions
Performance warranty temperature 10 ~ 35℃
Operating temperature/humidity/altitude Temperature 0 to 40°C/Humidity 5 to 80% RH ≤ 30°C (no condensation),
55% RH or less 40°C (no condensation)/Altitude 2000m or less
Standard Accessories
Probes (one for each channel), power cord (1), front panel cover (1), manual (CD-ROM) (1), user's guide (1)
Option
GPIB interface
DS-576
(Factory option)
GPIB: IEEE488.2
Probe power supply
DS-579
(Factory option)
IWATSU ELECTRIC active probe power supply 2 Series