Digital Oscilloscope "ViewGo II" DS-5600A Series Options
Dedicated Options
DS-576
GPIB interface
DS-577
AUX I/O option (CH1/CH2 output)If you implement the DS-577 option, the standard AuxOut terminal is deleted. Therefore, the functions of "Trigger output" and "Pass/Fail judgment output" output using the AuxOut terminal will not be available.
Output terminal | AUXI/O1 | Output CH1 input signal with offset voltage added |
---|---|---|
AUXI/O2 | Output CH2 input signal with offset voltage added | |
Each CH output specifications | Output resistance | 50Ω±5 % |
Offset | ±30mV (at 50 Ω termination) | |
Frequency characteristics | Maximum frequency bandwidth/2 (-3 dB, at 50Ω termination) |
|
Output voltage sensitivity | 30 mV/div±10 % (At 50Ω termination) |
DS-578
AUX I/O option (CH1 output) If the DS-578 option is implemented, the position of the AuxOut terminal installed as standard will be changed.
The left side facing the rear side becomes the CH1 output, and the position of the AuxOut terminal is changed to the right side.
Output terminal | AUXI/O1 | Output CH1 input signal with offset voltage added |
---|---|---|
Output Specifications | Output resistance | 50Ω±5 % |
Offset | ±30mV (at 50 Ω termination) | |
Frequency characteristics | Maximum frequency bandwidth/2 (-3 dB, at 50Ω termination) |
|
Output voltage sensitivity | 30 mV/div±10 % (At 50Ω termination) |
DS-579
Probe Power Options
Number of output channels | 2 |
---|---|
Maximum output power | 9 VAmax * Use the 2CH so that the total current consumption does not exceed 750mA. |
Offset Output voltage adjustment function * FET probe-only valid functions |
From the Utilities menu of the ViewGo II Series unit, it can be set for each channel. |
Compatible probes | Current probe:SS-531** / SS-530** / SS-521** / SS-520** / SS-570** / SS-560** / SS-550** / SS-540** / SS-270 / SS-260 / SS-250 / SS-240A / SS-240 FET probes:SFP-5A / SFP-4A High voltage differential probe SS-320 |
** The above probes require a power conversion cable SS-200-IW.
IE-1226 (Made-to-order)
The VGA Video OUT option waveform screen can be output to an external display. * After implementing IE-1226, DS-579 cannot be used.
Carrying bag
Commercial product, multi-purpose bag
Standard probe
SS-0130R
Frequency bandwidth:DC~200MHzInput RC:10MΩ // 12.5pFAttenuation:10:1Length:1.5mCompatible models:
DS-551xA / DS-552xA / DS-541x / DS-542x / DS-561xA / DS-562xA / DS-541xA / DS-542xA / DS-561x / DS-562x
SS-101R
(Discontinued)
Frequency bandwidth:DC~500MHzInput RC:10MΩ // 12pFAttenuation:10:1Length:1.2mCompatible models: DS-553xA / DS-555xA / DS-563x / DS-565x / DS-563xA / DS-565xA
SS-150R
(SS-101R successor probe)
Frequency bandwidth:DC~500MHz Input RC:10 MΩ±2 % // 12.5pF±10%Attenuation:10:1Length:1.5mCompatible models:DS-553xA / DS-555xA / DS-563x / DS-565x / DS-563xA / DS-565xA
High voltage differential probe
SS-320
Frequency bandwidth:DC~100MHzAttenuation:50:1, 500:1Maximum differential operating voltage:
±1,400 V(DC + AC peak, 500:1)
±140 V(DC + AC peak, 50:1)Full length:2m
DS-579
Probe Power OptionsProbes compatible with probe power unitsfor ViewGo II are available here.
Probe Power Supplies PS-25
Power supply for SFP-5A/4A/SS-320 Power output:±12V (±5%, 120mA max) x 2chOffset signal output:±1.6V(in combination with SFP-5A/4A, offset adjustment of ±20V is possible)
Active Probes
DS-579
Probe Power OptionsProbes compatible with probe power unitsfor ViewGo II are available here.
Probe Power Supply PS-25
Power supply for SFP-5A/4A/SS-320Power output:±12V (±5%, 120mA max) x 2chOffset signal output:±1.6V(in combination with SFP-5A/4A, offset adjustment of ±20V is possible)
High Voltage Probes
PHV 1000-RO
Attenuation ratio:100:1, Input RC:50MΩ 7.5pFFrequency band:400MHz (for single probe)Capacitance variable range:10-50pF
Length:2m
HV-P30A
DC to 50MHz, DC-30kV, pulse 40kV
HV-P60A
DC to 50MHz, DC-60kV, pulse 80kV
* High-voltage probes should be selected after checking the derating characteristics.
Current probe
Rogowski-Coil Current Probe SS-28xA Series
Frequency band:fL ~ 30MHzMaximum peak current:3,000ASensor temperature range:-40°C ~ +125°C
Rogowski-Coil Current Probe SS-29x Series
Frequency band:S-type -fL to 20MHz, L-type -fL to 10MHzMaximum peak current:12kASensor temperature range:-40℃~+125℃
DS-579
Probe Power OptionsProbes compatible with probe power unitsfor ViewGo II Series are available here.
* In the case of a single probe, a calibration certificate, traceability system figure, and inspection report will be charged separately.